Vue de la page 96
CobraNet Programmer’s Reference
Management Interface Variable Reference
DS651PM25 ©Copyright 2006 Cirrus Logic, Inc. 97
Name
audioLoopDst
Description
Describes destination audio routing channels for performing a local audio loopback function. See
audioLoopSrc for a complete description.
Host Address
0x35000
SNMP Object ID
1.3.6.1.4.1.2680.1.1.5.3.1.3
Count
8 in standard firmware build
Type
Integer
Attributes
Read/write - Persistent
Default Value
0
Implemented Version
2.1.0
Name
audioOutputs
Description
List of audio output routing channels. Audio output data must be cleared to silence if data is not
received over the network for the channels. By default 33 - 64 are used as outputs but these
variables may be configured by the manufacturer according to the audio I/O configuration of the
hardware. The user should not change these values.
Host Address
0x36000
SNMP Object ID
1.3.6.1.4.1.2680.1.1.5.4.1.2
Count
32
Type
Integer
Attributes
Read/write - Persistent
Default Value
{33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 48, 49, 50, 51, 52, 53, 54, 55, 56, 57, 58,
59, 60, 61, 62, 63, 64}
Implemented Version
2.1.0