Parameter Description Default (ms) Min (ms) Max (ms)
Target Settings continued
Timing Parameters
The Gemini software allows you to set up all of the relevant timings for entering and exiting
‘Serial Programming Mode’. The default timings for T1...T6 have been chosen to suit a C/R
network.
T1 Safe Shutdown Delay 200 1 4,000
Time between the PROG_ACTIVE line
being asserted to the PROG_RESET being
asserted
T2 RESET Hold Time 200 1 4,000
Time from RESET being asserted to the
Vpp generator being switched on or off
(if Vpp is required)
T3 RESET Release Time 500 1 4,000
Time allowed for the target RESET circuit
to decay from Vcc to 0V once the
PROG_RESET line is released (i.e. tri-stated).
T4 Vpp Ramp Up Time 500 1 4,000
Time allowed for the Vpp generator
voltage to ramp up and settle at the final
specified Vpp value.
T5 Vpp Ramp Down Time 1,000 1 4,000
This is the time allowed for the Vpp
generator voltage to ramp down from the
specified Vpp value to Vcc.
T6 Reserved for future use - - -
Figure 23