Gemini Users Manual 109
:Sz# command has been sent
prior. If the coordinate selection is
valid the object status is set to
"Selected". From L4, V1.0 up.
:SB<n>#
Set LED Display Brightness
Value(from L1, V2.0 up)
n=0: 100% n=6: 6.6% n=7: blank
display n=8: test mode (all pixels
lit).
:SC<mm>/<dd>/<yy>#
0 if invalid or
1Updating planetary
data#
<24 blanks>#
Set Calendar Date: months mm,
days dd, year yy of the civil time
according to the timezone set. The
internal calendar/clock uses GMT.
:SE<hh>:<mm>:<ss># 1
Set Alarm Time from the civil
time hours hh, minutes mm and
seconds ss. The timezone must be
set before using this command.
:SG{+-}hh# 1
Set the number of hours by which
your local time differs from UTC.
If your local time is earlier than
UTC set a positive value, if later
than UTC set a negative value.
The time difference has to be set
before setting the calendar date
(SC) and local time (SL), since the
Real Time Clock is running at
UTC.
:SL<hh>:<mm>:<ss># 1
Set RTC Time from the civil time
hours hh, minutes mm and
seconds ss. The timezone must be
set before using this command.
:Sd{+-}<dd>{*°}<mm>#
or
:Sd{+-
}<dd>{*°:}<mm>:<ss>
0 if invalid or
1 if valid
Sets the object's declination. It is
important that the :Sr# command
has been send prior. Internal
calculations are done that may
take up to 0.5 seconds. If the
coordinate selection is valid the
object status is set to "Selected".
:SM<name string># 1
Set name of the first site stored.
The minimum length of site name
strings is 1 byte, the maximum
length 15 bytes.